Arkansas HVACR NewsMagazine January 2025

HVACR NewsMagazine January 2025

Tech News

High Subcooling is an indication that more than the designed amount of refrigerant is “backing up” or “packed” into the condenser. This can be caused by overcharge, restriction (such as a contaminated line drier or kinked liquid line), or an undersized or failing closed metering device. Keep in mind that the subcooling can often read in range on a system that still has issues. This is often because the previous tech simply “set the charge” by subcooling without fully testing all aspects of the equipment, such as airflow. — Bryan P.S. – If you want to learn more about subcooling, check out this training video. This article was furnished by Brian Orr and HVAC School For Techs by Techs. We appreciate them sharing their excellent articles and encourage our readers to subscribe to their site at https://hvacrschool.com/start/

Apprenticeship Why

• Good for the Contractor / Dealer o Reduces callbacks • Good for the Consumer

o One service call which saves them money as well as the number days they have to take off to meet the service tech. • Good for the Apprentice o Provides a career path with expectations and rewards. Pay raise ever six months (as long as class and work progress are accomplished)

Coming Soon Stay Tuned

2025 A Year for Questions

Made with FlippingBook flipbook maker